View RSS Feed

All Blog Entries

  1. A/C CCU Board service – how not to… 02

    by , 01-06-2016 at 01:49 PM (Today at Atelier Kaz - ex-Honda R&D, F1, Indy/CART engineer)
  2. A/C CCU Board service – how not to… 01

    by , 01-06-2016 at 12:53 PM (Today at Atelier Kaz - ex-Honda R&D, F1, Indy/CART engineer)










    While working on another NSX, one owner contacted me for the A/C CCU board issue.
    He was not getting the air from the footwell section and no temperature control.

    He carried out the Self Diag test and it showed failure at F: Air Mix control and G: MODE motor.
    He also told me that the board was serviced by someone in the past.

    I normally don’t like dealing with the board that
    ...
  3. Cooling Sys, Health Check, etc 08

    by , 29-05-2016 at 11:50 AM (Today at Atelier Kaz - ex-Honda R&D, F1, Indy/CART engineer)






    ...
    Tags: hub puller Add / Edit Tags
    Categories
    Health Check Service
  4. Cooling Sys, Health Check, etc 07

  5. Cooling Sys, Health Check, etc 06

    by , 29-05-2016 at 11:31 AM (Today at Atelier Kaz - ex-Honda R&D, F1, Indy/CART engineer)






    ...