Today at Atelier Kaz - ex-Honda R&D, F1, Indy/CART engineer

Air Con CCU Board Service 01

Rate this Entry
Started to work on another CCU board. The owner also sent in the three Bose speaker AMPs as well so will be working on them later. This is another very good example on the importance of preventative measure. The owner was not feeling any issues at all with his A/C but decided to send the CCU board to my place.Very good decision....Click image for larger version. 

Name:	C15Removed.JPG 
Views:	1666 
Size:	166.4 KB 
ID:	9003
Click image for larger version. 

Name:	C22Removed.JPG 
Views:	1663 
Size:	184.7 KB 
ID:	9004
After looking at the board, once again, I decided not to connect it to my NSX as I was scared with the condition of diode array DM11 and capacitor C15 area. There were so many leakage from the capacitors and some of them were quite serious. Click image for larger version. 

Name:	C44Removed.JPG 
Views:	476 
Size:	188.6 KB 
ID:	9006
Click image for larger version. 

Name:	DM11.JPG 
Views:	484 
Size:	163.1 KB 
ID:	9005
At the end, 8 out of 13 capacitors were leaking the acid.The track and the pad especially around C44 and DM11 were seriously damaged. Probably, the owner didn’t notice some of the air outlet mode issues. This week, I decided to focus on writing the documents for the Health Check report, future service quote, business planning, etc but looks like, I need to spend more time on the electronics side again…. Kaz

Updated 05-06-2012 at 09:54 AM by Kaz-kzukNA1

Categories
A/C CCU Board Service , Heater, A/C , Electronics

Comments