Introduction Failure of the Climate Control Unit (CCU) is a common fault, affecting nearly any NSX. In almost any case, capacitor replacement and track repair will fix all issues. Depending on the state of the PCB, further damage to other components can happen, though. Diagnostic - Transistor Issues The following error cases and ways of repairing have been identified so far. These faults can be caused by major acid leakage affecting nearby transistors. ...
Updated 14-04-2024 at 03:52 PM by Heineken
...
A while ago, another owner contacted me after triggering the EPS warning light. He contacted me previously but at that time, he managed to fix it by using another EPS controller or replacing the internal relays by someone. Unfortunately, the issue came back and despite trying his own refurbished spare unit, the warning light was still there so call for the help. ...
Now that managed to recover the power, full refurbishment in progress. OP AMP section ...