Introduction Failure of the Climate Control Unit (CCU) is a common fault, affecting nearly any NSX. In almost any case, capacitor replacement and track repair will fix all issues. Depending on the state of the PCB, further damage to other components can happen, though. Diagnostic - Transistor Issues The following error cases and ways of repairing have been identified so far. These faults can be caused by major acid leakage affecting nearby transistors. ...
Updated 07-12-2024 at 09:44 PM by Heineken